Enter a chemical by name or CAS number and see which Aceppe glove models are actually tested against it under EN ISO 374 — with the permeation level, the degradation rate, and the certificate behind it. Free, no signup. Data comes from our suppliers' EU type-examination certificates and test reports, not from generic charts.
13 chemicals are covered by real test data on specific Aceppe glove models. Click a row to run it. Concentrations are the ones stated on the certificates — results apply only at that concentration.
| EN 374 code | Chemical | CAS | Tested at | Models with data |
|---|
The level is the breakthrough time of the slowest test specimen — the time until the chemical first permeates the glove at a standardised rate. Higher is better.
| Level | Breakthrough time | Meaning |
|---|---|---|
| Level 1 | > 10 min | Splash protection only |
| Level 2 | > 30 min | Short contact |
| Level 3 | > 60 min | Up to an hour |
| Level 4 | > 120 min | Up to two hours |
| Level 5 | > 240 min | Up to four hours |
| Level 6 | > 480 min | Full shift (8 hours) |
A level is a threshold band, not a measured time — unless the card says "measured", the minutes shown are the band the level guarantees. Only KINGFA KG-1101 has per-specimen measured minutes on file.
Type A — at least 6 test chemicals at Level 2 or above. Type B — at least 3 chemicals. Type C — at least 1 chemical at Level 1. The letters printed under the flask pictogram are the codes of the chemicals the glove was tested against.
Degradation is the change in the glove's puncture strength after contact with the chemical, in percent. A positive number means strength lost; a negative number means puncture resistance increased. A passing level does not mean the glove is undamaged. Xingyu N1555 passes 65% nitric acid at Level 2 but loses 98.1% of its puncture strength — the glove is technically "passing" and practically unusable for long wear. This selector always shows degradation next to the level, and warns when it is severe (40% or more).
Our generic compatibility checker rates nitrile "Good" against n-heptane. The test data says it depends on thickness: the thin disposable KINGFA KG-1101 (0.08–0.10 mm) failed Level 1 — its fastest specimen broke through in under 1 minute — while the thick industrial Xingyu N1555 (≥ 0.38 mm) passed at Level 6. Same material, opposite result. That is why this selector recommends by model, not by material.
EU type-examination certificates (Module B) and the underlying SATRA, CTC and SGS test reports for six glove models from our suppliers: Junda (JD-N902, JD-L902), Kingfa (KG-1101/1107), Shandong Xingyu (N1555), Nantong Jiadeli (NSL1888/NL2072) and Tron Power (TRON 1000 Chemical). Certificate numbers, issuing bodies and expiry dates are shown on every result. No data is borrowed from other manufacturers.
The selector falls back to our Chemical Glove Compatibility Checker, which rates 60 chemicals against six glove materials in general. That rating is a generic material rating — it is not a test result for a specific Aceppe model, and the page says so. For a chemical with no model data, confirm the choice with the manufacturer's own compatibility chart and your own testing before use.
No. Level 2 guarantees more than 30 minutes, not 60. Match the level to your contact time: 30–60 minutes needs Level 3, 60–120 minutes needs Level 4, over 240 minutes needs Level 6. Use the contact-time filter above and the selector does the matching for you.
No mixture data exists in our certificates — every result applies to the single chemical at the stated concentration. Mixtures can behave differently from their components, so treat any mixture as untested and seek advice before use.
The test data is still real measured data, and the selector shows it. But an expired Module B certificate means the "CE certified" claim needs renewal first — confirm the renewal status with us before relying on the CE marking for that model. KINGFA KG-1101's Module B certificate expired 8 March 2026.
No. Breakthrough time is measured in a lab at 23 °C with a standardised permeation rate. Heat, movement, stretching and reuse all shorten it in real use. Treat the level as a ranking tool, not a wear-time promise, and change gloves on a schedule with a safety margin.
Model data: EU type-examination certificates — SATRA 2777/15014-03/E00-00 (JD-N902, valid to 16 Jun 2030), SATRA 2777/15088-03/E00-00 (JD-L902, valid to 28 Aug 2030), SATRA 2777/15940-05/E00-00 (KG-1101, expired 8 Mar 2026), SATRA 2777/23413-01/E00-00 (N1555, valid to 16 Jan 2028), CTC 0075/1265/162/07/25/1536 (NSL1888/NL2072, valid to 9 Jul 2030), SGS Fimko 0598/PPE/25/3427 Issue 1 (TRON 1000, valid to 22 May 2030) — plus the underlying SATRA test reports CHM0305281/2047/EN/A and /EN/B for KG-1101. Generic fallback ratings: our Chemical Glove Compatibility Checker dataset (60 chemicals, consensus of published compatibility charts).
Reference only. Results apply to the single chemical at the stated concentration, at 23 °C, on the tested model. They do not cover mixtures, other concentrations, other models, or reuse. Always verify with the certificate original and conduct your own testing before use. This tool assists a risk assessment; it does not replace one. Aceppe is not liable for glove selection decisions made from this tool.